GE transformer models and specs. Shipping throughout the US and the world of a variety of brands of power. GUIDELINES FOR DETERMINING PCB STATUS. 1976 transformer) General Electric Company. Serial numbers with this format indicate transformer. I have a Westinghouse 333kva oil filled transformer. Serial number 89A103493. Primary voltage is 13.2kva. Distribution Power Transformers Prolec GE India North America Canada USA Mexico Europe Spain UK Turkey France. Reports available by serial number of the transformer. Download nurarihyon no mago s2 360. General Electric Date Codes The breakdown for General Electric Serial Numbers is: 1st Alpha Character = Month Manufactured 2nd Alpha Character = Year Manufactured GE (USA) - Month Code Code Month A January D February F March G April H May L June M July R August S September T October V November Z December GE (USA) - 12 Year Cycling Code Code Year Year Year F 1991 2003 G 1980 1992 2004 H 1981 1993 2005 L 1982 1994 2006 M 1983 1995 2007 R 1984 1996 2008 S 1985 1997 2009 T 1986 1998 2010 V 1987 1999 2011 Z 1988 2000 2012 A 1989 2001 2013 D 1990 2002 2014. Submit G2277 (2 Units Available) 132 / 176 / 220 MVA HV of 380 kV and 1425 kV BIL LV of 13.8 x 13.8 kV and 250 kV BIL OLTC at HV Z = 13.0% @ 110 MVA 60 Hz. G2277 - Click here for additional details G2044 (1 Unit Available) 130/ 180 / MVA HV of 400 kV and 1425 kV BIL LV of 18kV and 250 kV BIL OLTC at HV Z = 14.75% @ 180 MVA 60 Hz. G2044 - Click here for additional details G2092 (1 Unit Available) 170 / 240 MVA HV of 230 kV and 1050 kV BIL LV of 18kV and 250 kV BIL OLTC at HV Z = 14.75% @ 240 MVA 60 Hz. G2092 - click here for additional details More Details To Follow About Prolec G.E. And These Units With more than 300,000 MVA installed worldwide in more of 35 countries around the world; Prolec GE has the engineering and manufacturing expertise to design, build, optimize and deliver solutions to the electric industry. Prolec GE has offered as an additional scope of services to any transaction, will customize and work directly with the buyer to modify any of the units as necessary to ensure a proper fit. Prolec GE transformers are used in a wide range of utilities, commercial and industrial applications. High-grade materials, combined with state-of-art technology in our design and manufacturing systems are key elements of a transformer that will deliver years of high reliability service. Each transformer receives all standard commercial tests in accordance with ANSI, IEEE, CSA and IEC, with test reports available by serial number of the transformer. Polarity of windings & angular displacement Ratio No-load loss & exciting current Load loss & impedance Lighting impulse (class II) Low-frequency dielectric tests Applied voltage tests on all windings Insulation power factor (class II) Induced tests Partial discharge in micro volts (class II) Partial discharge in Pico coulombs (class II) Dissolved gas analysis (class I) Temperature rise Zero phase sequence Front of wave Switching surge Sale in conjunction with.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |